Home Email this page Print this page Bookmark this page Decrease font size Default font size Increase font size
Noise & Health  
 CURRENT ISSUE    PAST ISSUES    AHEAD OF PRINT    SEARCH   GET E-ALERTS    
 
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Email Alert *
Add to My List *
* Registration required (free)  
 


 
   Abstract
  Introduction
  Present Study
   Noise Exposure M...
  Results
   Audiometric Meas...
  Results
  Conclusion
   References
   Article Figures
   Article Tables
 

 Article Access Statistics
    Viewed2062    
    Printed74    
    Emailed0    
    PDF Downloaded17    
    Comments [Add]    

Recommend this journal

 


 
  Table of Contents    
ORIGINAL ARTICLE  
Year : 2018  |  Volume : 20  |  Issue : 93  |  Page : 42-46
Noise exposure and hearing loss in classical orchestra musicians: A five-year follow-up

1 Department of Psychology, Ryerson University, Toronto, ON, Canada
2 Musician Clinic of , Ryerson University, Toronto, ON, Canada
3 Canadian Federation of Musicians, Ryerson University, Toronto, ON, Canada
4 School of Occupational and Public Health, Ryerson University, Toronto, ON, Canada

Click here for correspondence address and email
Date of Web Publication18-Apr-2018
 
  Abstract 


Introduction: This study is a follow-up to prior research from our group that attempts to relate noise exposure and hearing thresholds in active performing musicians of the National Ballet of Canada Orchestra. Materials and Methods: Exposures obtained in early 2010 were compared to exposures obtained in early 2017 (the present study). In addition, audiometric thresholds obtained in early 2012 were compared to thresholds obtained in early 2017 (the present study). This collection of measurements presents an opportunity to observe the regularities in the patterns of exposure as well as threshold changes that may be expected in active orchestra musicians over a 5-year span. Results: The pattern of noise exposure across instrument groups, which was consistent over the two time points, reveals highest exposures among brass, percussion/basses, and woodwinds. However, the average noise exposure across groups and time was consistently below 85 dBA, which suggests no occupational hazard. These observations were corroborated by audiometric thresholds, which were generally (a) in the normal range and (b) unchanged in the 5-year period between measurements. Conclusion: Because exposure levels were consistently below 85 dBA and changes in audiometric thresholds were minimal, we conclude that musicians experienced little-to-no risk of noise-induced hearing loss.

Keywords: Hearing loss, noise exposure, symphonic orchestra

How to cite this article:
Behar A, Chasin M, Mosher S, Abdoli-Eramaki M, Russo FA. Noise exposure and hearing loss in classical orchestra musicians: A five-year follow-up. Noise Health 2018;20:42-6

How to cite this URL:
Behar A, Chasin M, Mosher S, Abdoli-Eramaki M, Russo FA. Noise exposure and hearing loss in classical orchestra musicians: A five-year follow-up. Noise Health [serial online] 2018 [cited 2020 Sep 22];20:42-6. Available from: http://www.noiseandhealth.org/text.asp?2018/20/93/42/230366



  Introduction Top


Qian et al.[1] conducted a noise exposure survey on performing musicians of the National Ballet of Canada Orchestra. The survey was executed using dosimeters running for the entire duration of rehearsals and performances of the ballet Romeo and Juliet by Sergei Prokofiev. On the basis of measured levels and contractual limitations on playing time (360 h/year), the authors concluded that there was little-to-no risk of hearing loss associated with playing in the orchestra. However, the authors also acknowledged that the assessment of noise exposure might not be sufficient to make conclusions regarding risk to hearing health because of other types of noise exposures, not taken into account. Given the challenge of fully accounting for all possible types of noise exposure, another valuable way to address the occupational risks of musicians is to perform audiometric tests.

As a follow-up to the original study, Russo et al.[2] performed audiometric tests on the same population. Musicians were also asked to complete a questionnaire to obtain information about basic demographics and extra-occupational factors that might impact measured hearing thresholds. The objective was to gather all information necessary to predict hearing loss according to the International Organization for Standardization (ISO) 1999 standard.[3] For the study, musicians were divided into five groups exposed to the sound of similar characteristics. Brass, percussion/basses, and woodwinds all had higher levels of exposure than violins, violas, and cellos. There was essentially no difference between predicted and measured hearing losses at 3000, 4000, and 8000 Hz, while predicted hearing losses were underestimated at lower frequencies.

These findings are generally consistent with other noise-exposure surveys[4] and audiometric investigations.[5] However, the study by Russo et al.[2] study did provide reason for some concern about long-term hearing health, especially in brass players who had the highest levels of exposure and the poorest hearing thresholds. Nonetheless, it is important to acknowledge that at the time of testing, none of the groups had clinically significant hearing losses.


  Present Study Top


The present study represents a follow-up involving the same orchestral musicians tested by Russo et al.[2] The orchestra experienced minimal turnover in the period since the previous study allowing for meaningful comparisons across time points. The present study was divided into two parts.

The first part consisted of a noise exposure survey during 12 rehearsals and performances of the ballet Le Petit Prince with music by Kevin Lau. This piece of music is intended to be performed with lower sound levels than the Romeo and Juliet piece used in the previous study. We replicated the noise survey technique using noise dosimeters, which were recording for the entire duration of the piece (approximately 2.5 h) allowing for the determination of real noise exposure levels. Dosimeters were worn by different participants on different occasions. To assess the variations of the exposure between performances or rehearsals, some musicians donned the dosimeters more than once.

The second part of the follow-up study comprised hearing tests on all musicians. As in the previous study, we performed air conduction tests from 500 through 8000 Hz, to assess permanent threshold shifts that may have occurred since the time of last testing.


  Noise Exposure Measurements Top


Instruments and procedure

Noise exposure tests were conducted during 12 sessions of rehearsals and performances. Six dosimeters Casella Type Dbadge micro noise dosimeters were used. Unlike the instruments used in our prior studies,[1],[2] the dosimeters used in the current study had the advantage of being lighter (71 g) and having an integrated microphone, thereby being generally less obtrusive.

The routine of the measurements started with the technicians calibrating the dosimeters and checking their batteries. The musicians who were assigned to dawn the dosimeters on a particular day were informed one day in advance. On the day of the performance, they had the dosimeter fitted and turned on prior to congregating in the pit. Instruments were worn all the time, including during the intermission. At the end of the session, dosimeters were collected and their readings recorded.

It is well known that violins and violas provide performing musicians with rather asymmetrical exposure with left ears receiving higher sound levels than right ears. Because musicians were fitted with only one dosimeter, this difference was not assessed.

[Figure 1] shows a dosimeter attached to the shoulder of a musician. [Figure 2] shows the floor plan of the pit, with the locations of the players, and [Figure 3] shows a view of the orchestra pit.
Figure 1: Musician wearing a dosimeter

Click here to view
Figure 2: Floor plan of the pit

Click here to view
Figure 3: View of the pit

Click here to view



  Results Top


The measured Leq were converted to Lx,360 to reflect the reduced number of exposure hours experienced by an orchestra musician, (The duration of orchestra-related activities is stipulated in the musicians’ contracts.) as compared to an industrial worker (i.e., 360 vs. 2000). The formula for the conversion was:



This conversion amounts to an overall reduction of measured Leq of approximately 7.5 dB. As in Russo et al.,[2] we divided musicians into five groups on the basis of their location in the pit and the frequency content of their instruments: (1) violin I and violin II; (2) viola and cello; (3) woodwinds; (4) brass; (5) percussion and basses. Descriptive noise exposure statistics for each group are reported in [Table 1].
Table 1: Noise exposure (Lx,360) across each of the five groups

Click here to view


[Figure 4] is a comparison of exposures, where “previous” refers to those from Russo et al.[2] and “present” refers to results obtained in the present study. Although the exposure levels were generally higher in the previous study (a performance of Romeo and Juliet), the players tended to report that differences in subjective sound level was negligible. Once again, highest exposure levels were observed in brass, woodwinds, and percussion/basses.
Figure 4: Average and standard error of exposure (Lx,360) across the five groups (1–violins, 2–viola/cello, 3–woodwinds, 4–brass, 5–percussion/basses)

Click here to view



  Audiometric Measurements Top


Instruments and procedure

All 46 musicians who participated in this study had a full audiological workup and evaluation. This included a full history, assessment of both otologic health, otoscopy, and full range of clinical audiometry.

Admittance testing using Grason-Stadler Inc. (GSI) 39 Auto Tymp was included to rule out outer and middle ear disorders. Audiometry was performed using GSI16 clinical audiometer. Measurements were performed for the range 250–8000 Hz, including the 3000 and 6000 Hz inter-octave frequencies. Tests included word recognition assessment and speech detection thresholds. Both air conduction and bone conduction pure tone testing were performed to rule out any hearing loss that is conductive in nature.

All test equipment was calibrated and met national and international standards.[6],[7] The audiometric test booth meets the American National Standards Institute (ANSI) S3.1 standard (1999, R2013).[8] The clinical audiometer is calibrated annually and meets the ANSI S3.6 standard (2004, R2010).[9]

For musicians for whom a prior audiogram was available, we computed the difference between thresholds obtained across the two time points.

In addition to a full clinical evaluation performed by the second author (MC is a board certified audiologist), each musician received both written and verbal information regarding hearing loss prevention. In some cases, musicians’ hearing protection was recommended and fit.


  Results Top


[Figure 5] plots the audiometric pure tone average thresholds for each group collapsed across ears. As may be seen in the figure, there is a consistent mid- to high-frequency sensory-neural hearing loss with poorest sensitivity in the 4000–6000 Hz region. This pattern of sensitivity is highly consistent with that reported in Russo et al.[2] and suggests early stage hearing losses.
Figure 5: Average hearing loss in each group as assessed at test frequencies between 500 and 8000 Hz

Click here to view


The Canadian Standards Association (CSA) Z107.6 Standard Audiometric testing for use in hearing loss prevention programs[10] defines a significant threshold shift as:
  • an average shift of the hearing threshold levels at 2000, 3000, and 4000 Hz of ≥10 dB in either ear, or
  • a shift of the hearing threshold level of ≥15 dB at 3000 or 4000 in either ear.


[Table 2] summarizes the significant threshold shifts observed in each group over the 5-year span since Russo et al.[2]
Table 2: Threshold shifts based on comparison with Russo et al.[2]]

Click here to view




Across time points, exposure levels were highest across three instrument groups: brass, percussion/basses, and woodwinds. However, the exposure levels were consistently below 85 dBA and clinically significant changes that we observed in pure tone thresholds were minimal across groups. Furthermore, the small number of clinically significant changes are not clearly related to noise exposure. As a result, we conclude that the audiometric changes are most likely multifactorial in nature, likely to include occupational and non-occupational sources of noise, as well as aging. Nonetheless, in the present study as well as Russo et al.,[2] it was observed that those orchestral groups with the highest levels of exposure (brass, percussion/basses, and woodwinds) had the highest levels of hearing loss. Thus, it is entirely plausible that the occupational sources of noise represent a long-term hearing health risk for at least a subset of orchestra musicians.

Acknowledgements

We thank Adam Pham and Yang Luo, students in Ryerson University’s Occupational Health and Safety Program, for their assistance with noise exposure measurements. We also thank Francesca Copelli for her assistance with formatting text and figures.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Qian CL, Behar A, Wong W. Noise exposure of musicians of a ballet orchestra. Noise Health 2011;13:59-63.  Back to cited text no. 1
[PUBMED]  [Full text]  
2.
Russo F, Behar A, Chasin M, Mosher S. Noise exposure and hearing loss in classical orchestra musicians. Int J Ind Ergon 2013;43:474-8.  Back to cited text no. 2
    
3.
ISO 1999 (International Organization for Standardization), 1990. Acoustics: Determination of Occupational Noise Exposure and Estimation of Noise-induced Hearing Impairment. ISO TC/43 N1139. Revision of ISO 1999:1990. Second CD; March 2010.  Back to cited text no. 3
    
4.
Schmidt JH, Pedersen ER, Juhl PM, Christensen-Dlasgaard J, Andersen TD, Poulsen T et al. Sound exposure of symphony orchestra musicians. Ann Occup Hyg 2011;55:893-905.  Back to cited text no. 4
    
5.
Jansen EJ, Helleman HW, Dreschler WA, de Laat JA. Noise induced hearing loss and other hearing complaints among musicians of symphony orchestras. Int Arch Occup Environ Health 2009;82:153-64.  Back to cited text no. 5
    
6.
ANSI/ASA S3.6-2010 American National Standard Specification for Audiometers; 2010.  Back to cited text no. 6
    
7.
ANSI/ASA S3.1-1999 (R 2013) American National Standard Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms; 2008.  Back to cited text no. 7
    
8.
American National Standards Institute. Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms. ANSI S3. 1–1999 (2013). New York: American National Standards Institute; 1999.  Back to cited text no. 8
    
9.
American National Standards Institute. Specification for Audiometers. ANSI S3.6-2004 (R2010). New York: American National Standards Institute; 2004.  Back to cited text no. 9
    
10.
CSA Z107.6 Standard. Audiometric Testing for Use in Hearing Loss Prevention Programs. Canadian Standard Institution; 2016.  Back to cited text no. 10
    

Top
Correspondence Address:
Alberto Behar
Department of Psychology,Ryerson University, Toronto, ON, M5B 2K3
Canada
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/nah.NAH_39_17

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]
 
 
    Tables

  [Table 1], [Table 2]



 

Top