Home Email this page Print this page Bookmark this page Decrease font size Default font size Increase font size
Noise & Health  
 CURRENT ISSUE    PAST ISSUES    AHEAD OF PRINT    SEARCH   GET E-ALERTS    
 
 Next article
 Previous article
Table of Contents

Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Citation Manager
Access Statistics
Reader Comments
Email Alert *
Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed5749    
    Printed231    
    Emailed2    
    PDF Downloaded95    
    Comments [Add]    

Recommend this journal

 

 ARTICLES
Year : 2001  |  Volume : 3  |  Issue : 12  |  Page : 61--73

Objective evidence for tinnitus from spontaneous emission variability


1 Institute of Laryngology and Otology, University College, London, United Kingdom
2 National Hospital for Neurology and Neurosurgery, London, United Kingdom
3 ENT & Audiology Division, The Nofer Institute of Occupational Medicine, Lodz, Poland

Correspondence Address:
D Prasher
Institute of Laryngology and Otology, University College London,330 Gray’s Inn Road, London WC1X 8EE
United Kingdom
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 12678941

Rights and PermissionsRights and Permissions

Noise exposure is the most common cause for the generation of tinnitus. This study evaluated the variability of spontaneous emissions in industrial workers exposed to noise and reporting the presence of tinnitus in comparison with those exposed to noise but without tinnitus. The assumption being that exposure to noise leads to some instability within the cochlea, which alters the spontaneous emission activity. Thus those experiencing tinnitus may show greater variability than those without tinnitus. 198 mill workers in Poland exposed to noise levels between 85-95dBA for a mean of 12+6.6 years, 104 of whom had reported the presence tinnitus and 94 without tinnitus were evaluated for otoscopy, audiometry and otoacoustic emissions. The tests were repeated between 5-10 days in most subjects to check for variability. There were significant differences in the mean age, pure tone average, transient emissions amplitude and variability between groups with and without tinnitus. There were no significant differences between sessions for these measures in either group. Those with tinnitus had poorer thresholds by an average of around 15dB, and reduced TOAE of around 2.6dB compared with those without tinnitus. There are a number of factors such as age, pure tone thresholds and tinntius, which may be responsible for the reduction in emissions. For the purposes of examining SOAE stability, all SOAE peaks were classed as stable if SOAE frequency in the two sessions remained unchanged and variable if SOAE peaks were present in both sessions but shifted in frequency or present in one sessions and absent in the other. SOAE were present in 73.1% of tinnitus group and in 50% of non- tinnitus group. Of these 92% of the tinnitus group had present and variable SOAE whereas 48.9% of the non-tinnitus group did. Thus the positive predictive value was calculated at 65% for those with variable SOAE having tinnitus and significantly higher at 86% negative predictive value for those with stable SOAE having no tinntus. The likelihood ratio of tinnitus being present given that SOAE are present and variable is 1.87 and is significantly reduced for no tinnitus given that SOAE are present and stable at 0.156. This study has clearly demonstrated that the incidence of spontaneous emissions is higher in noise-exposed workers than previously observed and the stability from week to week is significantly lower in those with subjective tinnitus.






[FULL TEXT] [PDF]*


        
Print this article     Email this article